Manufacturing Industrial Electronic Solutions Since 1988
SYCON
Maximum Demand Management

Maximum Demand Controller 4300 SS

Maximum Demand Controller with one alarm point, one tripping point, programmable demand settings and intelligent demand switching.

SYCON 4300 SS Maximum Demand Controller
Product Overview

Maximum Demand Control

The SYCON 4300 SS is a Maximum Demand Controller designed to monitor electrical demand and provide alarm and tripping control. It provides one alarm point and one tripping point with potential-free outputs. Alarm and trip demand values can be set at site. The controller displays average KVA demand, instantaneous demand, RMS voltage, RMS current and demand-related settings.

Features

Designed for Reliable Industrial Operation

Key features of the SYCON 4300 SS.

One alarm point and one tripping point with potential-free outputs

Friendly user interface

Easy to install

Large 2 x 16 character alphanumeric LCD display

Continuous display of average KVA demand

Continuous display of instantaneous demand

Display of RMS voltage and RMS current

Selectable display of settings

Display of present and previous maximum demand

Trip status of contacts

Password protection for settings

Adjustable integration time of 15 minutes or 30 minutes

Programmable CT primary

Adjustable demand settings

Clock setting facility to match EB clock

Benefits

Engineering Benefits
That Matter

Designed to support dependable operation and efficient electrical system performance.

01

Provides alarm and tripping control based on configured demand values

02

Allows alarm and trip demand values to be set at site

03

Displays average and instantaneous demand for monitoring

04

Provides RMS voltage and RMS current information

05

Adjustable integration time supports different demand measurement requirements

06

Programmable CT primary allows configuration according to the current transformer

Technical Specifications

Technical Details

Product specifications for engineering evaluation and application selection.

Parameter
Specification
Product Type
Maximum Demand Controller
Voltage Input
415V AC -15%
Current Input
5A / 1A optional
Frequency
50Hz
Switching Contact
10A at 250V AC
Accuracy
1 digit
Switching Program
Intelligent (Best fit)
Display
Large alphanumeric LCD display, 2 x 16 characters
Integration Time
15 minutes or 30 minutes
Alarm Output
1 alarm point, potential-free
Trip Output
1 tripping point, potential-free
Dimensions
144 (L) x 144 (W) x 80 (D) mm
Panel Cutout
138 mm x 138 mm
Applications

Where It Fits

Typical applications for the SYCON 4300 SS.

Maximum demand control

Application

Electrical systems requiring demand alarm and trip control

Application

Industrial electrical systems

Application

Electrical systems requiring monitoring of average and instantaneous demand

Application
FAQs

Frequently Asked Questions

Answers to common questions about the SYCON 4300 SS.

The SYCON 4300 SS is a Maximum Demand Controller designed to monitor electrical demand and provide one alarm point and one tripping point with potential-free outputs.

Product Inquiry

Need the Right
SYCON 4300 SS for Your Application?

Share your electrical application or requirement with our engineering team. We can help you evaluate the product and determine its suitability for your system.