Manufacturing Industrial Electronic Solutions Since 1988
SYCON
Harmonic Assessment

Harmonic Analysis

Measure and analyse harmonic distortion to understand its impact on industrial electrical systems and identify appropriate corrective measures.

Industrial harmonic analysis and harmonic distortion assessment
The Problem

Why This Service
Matters

Understanding the underlying problem helps establish the right scope and approach for the engagement.

Electrical equipment experiences unexplained heating or malfunction.

Capacitor banks experience repeated problems.

Harmonic distortion is suspected in the electrical system.

Non-linear loads are affecting electrical system performance.

The facility needs measured information about harmonic distortion.

Scope of Service

What the Service
Covers

The scope is defined according to the requirements of the site, system and engagement.

Harmonic voltage measurement.

Harmonic current measurement.

Total harmonic distortion assessment.

Harmonic spectrum analysis.

Assessment of non-linear load behaviour.

Assessment of electrical system conditions associated with harmonics.

Identification of significant harmonic conditions.

Recommendations for appropriate corrective measures.

Methodology

How We Conduct the Service

A structured approach designed to understand the site, analyse the relevant conditions and deliver actionable engineering outcomes.

01

Understand the electrical system

Review the electrical distribution system, major loads and reported harmonic-related problems.

02

Identify measurement locations

Select suitable electrical points and operating conditions for harmonic measurements.

03

Measure harmonic parameters

Measure harmonic voltage, harmonic current and total harmonic distortion.

04

Analyse harmonic spectrum

Review the measured harmonic spectrum and identify significant harmonic components.

05

Assess system impact

Evaluate the measured harmonic conditions in relation to the electrical system and connected loads.

06

Identify probable causes

Relate measured harmonic conditions to relevant non-linear loads and system operating conditions.

07

Recommend corrective measures

Develop technically appropriate recommendations based on the measurement and engineering assessment.

Deliverables

What You
Receive

The engagement produces documented findings, analysis and recommendations appropriate to the agreed scope.

Harmonic voltage measurements.

Harmonic current measurements.

Total harmonic distortion assessment.

Harmonic spectrum analysis.

Identification of significant harmonic conditions.

Assessment of probable harmonic sources.

Engineering recommendations for corrective action.

Measured understanding of harmonic distortion.

Identification of significant harmonic components.

Better understanding of non-linear load impact.

Improved basis for harmonic mitigation decisions.

Better electrical system performance assessment.

Benefits

What the Service
Helps You Achieve

The service is intended to convert technical findings into practical actions that support better system performance and decision-making.

Industries

Industries We
Serve

Our services can be applied across industrial and commercial environments where electrical, energy and system performance need to be evaluated.

FAQs

Frequently Asked Questions

Answers to common questions about harmonic analysis.

Harmonic analysis is the measurement and assessment of harmonic components in an electrical system to understand waveform distortion and its possible causes.

Talk to SYCON

Need a Harmonic Analysis?

Share your site requirements with our engineering team and discuss the appropriate scope for your engagement.